Page 11 - Green Builder Magazine July 2015 Issue
P. 11

SPECIAL SECTION

Exposed Foundation Insulation

An excerpt from ICC’s Energy Code Essentials: Based on the 2015 International Energy
Conservation Code®

Energy Code Essentials: Based                                                                                                   Exposed Foundation Insulation 51
on the 2015 International
Energy Conservation Code®          EXPOSED FOUNDATION INSULATION
uses a straightforward, focused
approach to introduce code         The code requires insulation on the exterior foundation to be protected
users to the new requirements.     from physical damage and direct sunlight. Basement and crawlspace
Color illustrations and practical  walls and slab-edge insulation must be covered with a rigid, opaque,
on-the-job scenarios allow         weather-resistant material that covers the exposed material above grade
readers to gain confidence         and extends at least 6 inches below grade (Figure 5-10). [Ref. C303.2.1]
in their understanding of the      This protection contributes to maintaining the thermal design perfor-
material. This publication may     mance of the installed insulation.
be purchased by visiting the
ICC online store at                                                     WALL
www.iccsafe.org/GBessentials.                                           COVERING

                                                                        INSULATING
                                                                        SHEATHING

                                                           FOUNDATION                              RIGID INSULATION
                                                           INSULATION                    R-15 AT BASEMENT SLAB
                                                           PROTECTION
                                   FINISHED GRADE                                                     VAPOR BARRIER

                                       6 in. MINIMUM

                                                         DRAINAGE                        4 in. MINIMUM
                                                                   MAT                   COMPACTED GRANULAR

                                   R-10 RIGID INSULATION AT                              BASE
                                   FOUNDATION WALLS-TYP.

                                   FIGURE 5-10 Exposed foundation insulation protection
   6   7   8   9   10   11   12   13   14   15   16